DTM (Direct-To-Metal / Sur-Métal) anti-corrosion paint that can be used as a primer and finish for the protection of cladding walls and metal sheets.
One-component solution, easy and quick to apply on most kinds of vertical cladding and available in a wide choice of colors.RD-Metal Unicoat is easy to use on steel located in moderate corrosive environments or inside industrial buildings.
Primer/Finish rust preventive coating for metal sheets and claddings.
Single component coating for the protection of metallic objects. RD-Metal Unicoat is an excellent choice for the renovation of metallic objects located in low to moderate corrosive environments and can be applied directly on steel and weathered galvanized steel without having to blast the surface.
RD-Metal Unicoat is water-based, easy to handle, safe and has no fire risks.
It is a fast-drying coating system that greatly reduces downtime during installation.
Virtually odour free, it does not affect neighbouring occupants and can therefore be used in occupied buildings.
RD-Metal Unicoat is UV resistant, has a good resistance against weathering and can therefore be applied as primer and/or as finish. When applied by airless, RD-Metal Unicoat easily covers large flat surfaces with no overlaps and will protect the coated objects neat and tidy for numerous years. It is therefore is an excellent, fast and easy renovation system for claddings and coated metal sheets.
RD-Metal Unicoat is part of the SCS – Single Coating System - product group.
Iron, steel, weathered galvanized steel (> 1 year)
Neutral interior atmosphere of a dry and heated building– C1 | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
Primer/Finish | RD-Metal Unicoat | 200 / 8 | 95 / 3,8 | 0,20 L / 200 | > 15 years life expectancy |
Atmosphere with low degree of pollution: Rural areas, unheated buildings where condensation may occur – C2 | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
Primer | RD-Metal Unicoat | 191 / 7,7 | 90 / 3,6 | 0,19 L / 212 | > 15 years life expectancy |
Finish | RD-Metal Unicoat | 191 / 7,7 | 90 / 3,6 | 0,19 L / 212 | |
Total | 180 / 7,2 | 0,38 / 106 |
Urban and industrial atmospheres with moderate pollution, Coastal areas with low salt content, Indoor production areas with high humidity and some pollution – C3 | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
Primer | RD-Metal Unicoat | 234 / 9,4 | 110 / 4,4 | 0,23 L / 174 | > 10 years life expectancy |
Finish | RD-Metal Unicoat | 234 / 9,4 | 110 / 4,4 | 0,23 L / 174 | |
Total | 180 / 7,2 | 0,46 / 87 |
Renovation of coated side walls made of metal sheets / claddings | Wet film thickness in microns / mils | Dry film thickness in microns / mils | Consumption per m² / ft² per gallon | Comments | |
Primer | RD-Metal Unicoat (*) | 200 / 8 | 95 / 3,8 | 0,20 L / 200 | > 15 years life expectancy |
Finish | RD-Metal Unicoat | 200 / 8 | 95 / 3,8 | 0,20 L / 200 | |
Total | 190 / 7,2 | 0,40 / 100 |
(*) In case of corroded surfaces or when the objects are located in a more corrosive atmosphere (C4 or C5), it is advised to use RD-Elastometal as a prime coat.
A single coat is possible on previously painted surfaces in need of an aesthetic refreshment.
Risks of chemical spills, graffitis or nearby aggressive exhaust fumes/pollution:
The system can be top coated by one or two coats of RD-Hydrograff HP Clear High Gloss.
Indicated consumption is theoretical and does not consider potential losses during application. It can also be influenced by the porosity of the substrate.
Ambient temperature: minimum 5° C (41°F) – Optimal between 12° and 25°C (54° and 77°F).
Relative humidity: maximum 80 %
Surface temperature must be minimum 3°C (5°F) above dew point.
Brush, roller or airless (nozzle size: 013–015)
The substrate must be clean: dry, degreased and dust free. Non adhering elements such as older coatings or rust must be removed. Different types of surface preparation are possible:
1/ Remove rust manually or by power tool to ST2 – ISO 8501-1/SSPC SP2 or SP3.
2/ Blasting to SA 2½ - ISO 8501-1/NACE3/SSPC SP6.
3/ High pressure washing following SSPC SP12 WJ4.
Contact your RD Coatings representative in case of hesitation.
Product is ready-for-use. Dilute with maximum 3% water when applying by airless or in warm weather conditions (> 25°C / > 77°F).
Touch dry: +/- 2 hours
Recoatable: +/- 4 hours
Water
Mix well before use.
Satin: 15 +/- 5
White, RAL, NCS and bespoke colours.
Available on RD Coatings dispensing system.
1.3 +/- 0.05 g/cm³
In weight: 59 % +/-2
In volume: 47 % +/-2
100 - 120 P (Brookfield 20RPM)
< 60 g/L
Not flammable
24 months, keep away from frost and store away from heat.
SALT SPRAY | ISO 12944 / ASTM B117 / ISO 4628 |
ADHESION X-CROSS CUT | ISO 2409 |
ADHESION PULL-OFF TEST | ISO 4624 |
ABRASION RESISTANCE TABER | ASTM D4060 |
PENCIL HARDNESS | ASTM D3363 |
QUV TEST | ASTM D4587 / ASTM G53 /ISO 11507 |
Information related to hygiene and to safety can be found in the Safety Data Sheet available on request.
These specifications are given for information. Since the manufacturer is not able to check the application of the products, he cannot accept any responsibility for it. This technical data sheet replaces all previous editions.
DTM (Direct-To-Metal / Sur-Métal) anti-corrosion paint that can be used as a primer and finish for the protection of cladding walls and metal sheets.